Category:Residential Energy Storage Systems, solar battery storage, solar panel battery storage, solar battery for commercial, LFP battery, High Voltage battery,BYD battery
●4-channel MPPT design for maximum solar harvestin,
●Supports three-phase system architecture for versatile applications,
●100A passthrough ensures stable and secure operation
●Fully supports 100% unbalanced loads for more demanding use cases
●Independent grid and generator input; supports energy
storage from diesel generators,
●Compatible with AC-coupled systems, ideal for upgrading both
on-grid and off-grid setups
| Model | SNE5KLNA | SNE6KLNA | SNE7K6LNA | SNE8KLNA | SNE10KLNA |
| PV input data | |||||
| Max.PVinput power (kW) | 7,5 | 9 | 12 | 12 | 15 |
| Max.PV input voltage(V) | 500 | ||||
| Min.PV input voltage(V) | 120 | ||||
| Start-up voltage(V) | 120 | ||||
| MPPT voltage range(without battery)(V) | 120~500 | ||||
| MPPT voltage range@full-load(V) | 150~430 | ||||
| Rated PV input voltage(V) | 310 | ||||
| No.of MPPT trackers | 4 | ||||
| No.of strings per MPPT tracker | 1/1/1/1 | ||||
| Max.input current per MPPT(A) | 14/14/14/14 | ||||
| Max.short-circuit current per MPPT(A) | 22/22/22/22 | ||||
| Battery input data | |||||
| Battery type | Lithium-ion /Lead-acid | ||||
| Max.charge/discharge power(kW) | 5 | 6 | 7,6 | 8 | 10 |
| Battery voltage range(V) | 40~60 | ||||
| Rated battery voltage(V) | 48 | ||||
| Max.charging/discharging current(A) | 120/120 | 135/135 | 190/190 | 190/190 | 190/210 |
| Rated charge/discharge current(A) | 120/120 | 135/135 | 190/190 | 190/190 | 190/210 |
| Battery charging strategy | Self-adaption to BMS | ||||
| BMS communication | CAN | ||||
| ACoutput data(grid side) | |||||
| Rated output power(kW) | 5 | 6 | 7,6 | 8 | 10 |
| Max.apparent output power (kVA) | 5,5 | 6,6 | 8,4 | 8,8 | 11 |
| Rated grid voltage((V) | 110-127/208-240V split phase,240V single phase | ||||
| Grid voltage range (V) | 192~288 | ||||
| Rated grid frequency(Hz) | 60 | ||||
| Grid frequency range(Hz) | 55 to 65 | ||||
| Rated output current(A) | 20,8 | 25 | 31,7 | 33,3 | 41,7 |
| Max.AC output current(A) | 22,9 | 27,5 | 34,8 | 36,7 | 45,8 |
| Power factor | 0.8leading~0.8lagging | ||||
| Max.grid passthrough current(A) | 100 | ||||
| THDi | <3% | ||||
| Grid type | 2L+N+PE | ||||
| ACoutput data (load side) | |||||
| Rated output power(kW) | 5 | 6 | 7,6 | 8 | 10 |
| Max.apparent output power(kVA) | 5,5 | 6,6 | 8,4 | 8,8 | 11 |
| Rated output voltage(L-N/L1-L2)(V) | 120/240 | ||||
| Rated output frequency(Hz) | 60 | ||||
| Rated output current(A) | 20,8 | 25 | 31,7 | 33,3 | 41,7 |
| Max.AC output current(A) | 22,9 | 27,5 | 34,8 | 36,7 | 45,8 |
| Peak output power | 110%,30s /120%,10s/150%,0.02s | ||||
| Back-up switch time(ms) | <20 | ||||
| THDu | <2% | ||||
| Protection | |||||
| Supported protection | Arc fault protection,PV reverse polarity protection,Anti-islanding protection,Ground fault protection Leakage current protection,Insulation resistance detection,Backup output short circuit protection, AC under-voltage protection,AC output over-current protection,AC over-voltage protection, | ||||
| Surge protection | DC Type Ⅱ/AC Type Il | ||||
| Over voltage category | DC Type II / AC Type III | ||||
| Certifications and standards | |||||
| Certificates | FCC Part 15 Class B;UL1741SA all options,UL1699B,CSA 22.2;IEE1547 | ||||
| General data | |||||
| Ingress protection | IP65/NEMA 3R | ||||
| Operating temperature range(℃) | -25~+60 | ||||
| Cooling | Fan cooling | ||||
| Relative humidity | 0-95% | ||||
| Operating altitude(m) | 0~4,000(Derating above 2,000 altitude) | ||||
| Dimensions W*D*H(mm) | 450×820×240 | ||||
| Weight (kg) | 47 | ||||
| Topology (solar /battery) | Transformerless /Transformer | ||||
| Noise emission(dB) | 48 | ||||
| Display and communication | |||||
| Display | Touch panel | ||||
| Communication | RS485,4G(optional),Wi-Fi | ||||