Split-phase inverter(12-16kW)(battery voltage 48V)(LA)

Category:Residential Energy Storage Systems, solar battery storage, solar panel battery storage, solar battery for commercial, LFP battery, High Voltage battery,BYD battery

Product Features

Flexible & Efficient

●4-channel MPPT design for maximum solar harvestin,
●Supports three-phase system architecture for versatile applications,
●200A passthrough ensures stable and secure operation

Advanced Performance

●Fully supports 100% unbalanced loads for more demanding use cases

Intelligent & User-Friendly

●Independent grid and generator input; supports energy storage from diesel generators,
●Compatible with AC-coupled systems, ideal for upgrading both on-grid and off-grid setups

Benefits


●Support 7*24 remote service
Low Voltage Residential LiFePO4 Battery (BYD cell)

Application

● Solar Villa
● Telecom Base Station
● School & Office & Factory
● Shopping Mall
● Solar Farm
● Wind Power
Product Specification
ModelSNE12KLLA SNE16KLLA
PV input data
Max.PVinput power (kW)18 24 
Max.PV input voltage(V)500 
Min.PV input voltage(V)120 
Start-up voltage(V)120 
MPPT voltage range(without battery)(V)120~500
MPPT voltage range@full-load (V)150~430
Rated PV input voltage(V)310 
No.of MPPT trackers
No.of strings per MPPT tracker1/1/1/1
Max.input current per MPPT(A)16/16/16/16                          20/20/20/12020/20/20/120
Max.short-circuit current per MPPT(A)22/22/22/2225/25/25/25
Battery input data
Battery typeLithium-ion/Lead-acid
Max.charge /discharge power (kW)12 13 
Battery voltage range (V)40~58
Rated battery voltage(V)48 
Max.charging/discharging current(A)250/260260/280
Rated charge/discharge current(A)250/260260/280
Battery charging strategySelf-adaption to BMS
BMS communicationCAN
AC output data(grid side)
Rated output power (kW)12 16 
Max.apparent output power(KVA)13,2 16 
Rated grid voltage((V)110-127/208-240V split phase,240V single phase
Grid voltage range(V)240 
Rated grid frequency(Hz)60 
Grid frequency range(Hz)55~65
Rated output current(A)50 66,7 
Max.AC output current(A)55 73,3 
Power factor0.8leading~0.8lagging
Max.grid passthrough current(A)200 
THDi<3%
Grid type2L+N+PE
ACoutput data (load side)
Rated output power(kW)12 13 
Max.apparent output power(kVA)13,2 13,2 
Rated output voltage (L-N/L1-L2)(V)120/240
Rated output frequency(Hz)60 
Rated output current(A)50 54 
Max.AC output current(A)55 55 
Peak output power110%,30s /120%,10s /150%,0.02s
Back-up switch time(ms)<20
THDu<2%
Protection
Supported protectionArc fault protection,PV reverse polarity protection,Anti-islanding protection,Ground fault protection
Leakage current protection,Insulation resistance detection,Backup output short circuit protection,
AC under-voltage protection,AC output over-current protection,AC over-voltage protection,
Surge protectionDC Type Ⅱ/AC Type ll
Over voltage categoryDC Type II / AC Type III
Certifications and standards
CertificatesIEC62109-1-2;IEC61000-6-1/-3;IEC62477-1
General data
Ingress protectionIP65/NEMA 3R
Operating temperature range(℃)-25~+60
CoolingFan cooling
Relative humidity0-95%
Operating altitude(m)0~4,000(Derating above 2,000 altitude)
Dimensions W*D*H(mm)495×900×260
Weight(kg)55 
Topology(solar /battery)Transformerless/Transformer
Noise emission(dB)48 
 
DisplayTouch panel
CommunicationRS485,4G(optional),Wi-Fi

We will serve you the best products with the favorite prices

Contact

    en_USEnglish

    Inquiry Form

    Sustainable Solutions, Superior Performance