Split-phase inverter(5-10kW)(battery voltage 48V)(NA)

Category:Residential Energy Storage Systems, solar battery storage, solar panel battery storage, solar battery for commercial, LFP battery, High Voltage battery,BYD battery

Product Features

Flexible & Efficient

●4-channel MPPT design for maximum solar harvestin,
●Supports three-phase system architecture for versatile applications,
●100A passthrough ensures stable and secure operation

Advanced Performance

●Fully supports 100% unbalanced loads for more demanding use cases

Intelligent & User-Friendly

●Independent grid and generator input; supports energy storage from diesel generators,
●Compatible with AC-coupled systems, ideal for upgrading both on-grid and off-grid setups

Benefits


●Support 7*24 remote service
Low Voltage Residential LiFePO4 Battery (BYD cell)

Application

● Solar Villa
● Telecom Base Station
● School & Office & Factory
● Shopping Mall
● Solar Farm
● Wind Power
Product Specification
 ModelSNE5KLNASNE6KLNASNE7K6LNASNE8KLNASNE10KLNA
PV input data
Max.PVinput power (kW)7,5 12 12 15 
Max.PV input voltage(V)500 
Min.PV input voltage(V)120 
Start-up voltage(V)120 
MPPT voltage range(without battery)(V)120~500
MPPT voltage range@full-load(V)150~430
Rated PV input voltage(V)310 
No.of MPPT trackers
No.of strings per MPPT tracker1/1/1/1
Max.input current per MPPT(A)14/14/14/14
Max.short-circuit current per MPPT(A)22/22/22/22
Battery input data
Battery typeLithium-ion /Lead-acid
Max.charge/discharge power(kW)7,6 10 
Battery voltage range(V)40~60
Rated battery voltage(V)48 
Max.charging/discharging current(A)120/120135/135190/190190/190190/210
Rated charge/discharge current(A)120/120135/135190/190190/190190/210
Battery charging strategySelf-adaption to BMS
BMS communicationCAN
ACoutput data(grid side)
Rated output power(kW)7,6 10 
Max.apparent output power (kVA)5,5 6,6 8,4 8,8 11 
Rated grid voltage((V)110-127/208-240V split phase,240V single phase
Grid voltage range (V)192~288
Rated grid frequency(Hz)60 
Grid frequency range(Hz)55 to 65
Rated output current(A)20,8 25 31,7 33,3 41,7 
Max.AC output current(A)22,9 27,5 34,8 36,7 45,8 
Power factor0.8leading~0.8lagging
Max.grid passthrough current(A)100 
THDi<3%
Grid type2L+N+PE
ACoutput data (load side)
Rated output power(kW)7,6 10 
Max.apparent output power(kVA)5,5 6,6 8,4 8,8 11 
Rated output voltage(L-N/L1-L2)(V)120/240
Rated output frequency(Hz)60 
Rated output current(A)20,8 25 31,7 33,3 41,7 
Max.AC output current(A)22,9 27,5 34,8 36,7 45,8 
Peak output power110%,30s /120%,10s/150%,0.02s
Back-up switch time(ms)<20
THDu<2%
Protection
Supported protectionArc fault protection,PV reverse polarity protection,Anti-islanding protection,Ground fault protection
Leakage current protection,Insulation resistance detection,Backup output short circuit protection,
AC under-voltage protection,AC output over-current protection,AC over-voltage protection,
Surge protectionDC Type Ⅱ/AC Type Il
Over voltage categoryDC Type II / AC Type III
Certifications and standards
CertificatesFCC Part 15 Class B;UL1741SA all options,UL1699B,CSA 22.2;IEE1547
General data
Ingress protectionIP65/NEMA 3R
Operating temperature range(℃)-25~+60
CoolingFan cooling
Relative humidity0-95%
Operating altitude(m)0~4,000(Derating above 2,000 altitude)
Dimensions W*D*H(mm)450×820×240
Weight (kg)47 
Topology (solar /battery)Transformerless /Transformer
Noise emission(dB)48 
Display and communication
DisplayTouch panel
CommunicationRS485,4G(optional),Wi-Fi

We will serve you the best products with the favorite prices

Contact

    en_USEnglish

    Inquiry Form

    Sustainable Solutions, Superior Performance